Annals
Established in 1927 by the American College of Physicians
:
Advanced search
 
box Article
 arrow  Table of Contents                
space
 arrow  Abstract of this article Free
space
 arrow  Figures/Tables List
space
 arrow  Articles citing this article
space
box Services
 arrow  Send comment/rapid response letter
space
 arrow  Notify a friend about this article
space
 arrow  Alert me when this article is cited
space
 arrow  Add to Personal Archive
space
 arrow  Download to Citation Manager
space
 arrow  ACP Search                        
space
 arrow  Get Permissions
space
box Google Scholar
 arrow  Search for Related Content
space
box PubMed
Articles in PubMed by Author:
  arrow  McDonald, C. J.
space
  arrow  Dexter, P. R.
space
 arrow  Related Articles in PubMed
space
 arrow  PubMed Citation
space
 arrow  PubMed
space

DIABETES CARE AND HEALTH SYSTEMS

The Promise of Computerized Feedback Systems for Diabetes Care

right arrow Clement J. McDonald, MD; J. Marc Overhage, MD, PhD; William M. Tierney, MD; Gregory R. Abernathy, MD; and Paul R. Dexter, MD

1 January 1996 | Volume 124 Issue 1 Part 2 | Pages 170-174

Feedback control is an important mechanism for reaching a targeted goal.Biologic examples range from achieving the appropriate blood pressure level to glycemia control. Computer-based feedback control systems have many potential applications in medicine. Closed-loop systems directly sense the state of the patient and then deliver an intervention without human action. Closed-loop systems have been used to control postoperative fluid infusion, reduce malignant hypertension to a reasonable range through nitroprusside infusions, and control continuous insulin infusions—in effect, an artificial pancreas. Sensory problems have limited the direct application of closed-loop systems to date; most current medical uses of computer-based feedback control are open loop, where a human is interposed between the suggested intervention and the delivered treatment.

Because many variables important to the management of diabetes are objective, many opportunities exist for open-loop control in diabetes management. Open-loop systems have already been used to suggest insulin dosage adjustments and treatments for hypercholesterolemia and to remind physicians of various interventions to reduce the complications of diabetes mellitus. However, existing applications have only scratched the surface. Many more facets of diabetes management could be standardized and assisted by open-loop control systems if the management rules could be more exactly specified, a task requiring substantial time commitments by diabetologists. Efforts to translate existing knowledge bases into precise guidelines will be helpful, but new primary studies and decision analyses are needed to define the optimal use of some interventions.


Feedback control has been a part of human experience since the time of the Babylonians, who used a system of floats to control the flow of water through an irrigation system. When the water level of an irrigation stream became too low, the link between the float and sluice gate caused the gate to open wider and increase the flow [1]. Of more recent vintage is the home thermostat. As the temperature decreases, a thermosensitive coil trips the circuit that turns on the furnace. The airplane autopilot is the most sophisticated everyday example of feedback control. Sensors report the plane's air speed, acceleration, yaw, and pitch to the autopilot computer, and the computer then adjusts the control surfaces or engine speed to steer the plane to its programmed destination. In these examples, the system "gathers" its own data, makes a "decision," and initiates an adjustment. In control theory, variables such as the level of water in the irrigation ditch or the room temperature, which define the system and the goals of the feedback control, are called state variables. Variables such as the height of the sluice gate or the on-off switch to the furnace, which can be used to change the state of the system, are called control variables.

Human physiology provides many examples of natural feedback control systems. The baroreceptors in the aortic arch continuously measure physiologic variables that reflect blood pressure and intravascular volume. Neural circuits trigger corrective responses such as increased vascular tone and heart rate when a drop in the pressure is sensed, which might occur, for instance, with a change in posture. Glucostasis in a nondiabetic patient has the serum glucose level as the state variable; insulin output and the degree of gluconeogenesis are some of the control variables involved. Sensors in the ß-cell detect rising glucose levels after a meal and trigger an outflow of insulin to reduce the levels.

Much disease management can be described as feedback control. For instance, we monitor blood pressure. If it is too high, we start with low doses of blood pressure medication and increase the dose as needed to titrate the blood pressure to normal range. We measure activated partial thromboplastin time (APTT) levels when anticoagulating patients with heparin and increase or decrease the rate of heparin infusion according to the APTT level. Diabetes management is the archetypal feedback control system. It has easily measurable state variables (for example, the blood glucose level), control variables (for example, the dose of insulin), and rules (algorithms) that tell how to adjust the control variables according to the value of the state variables. Orders for sliding-scale insulin provide a simple example of a control system: Give 2 units of insulin if the serum glucose level is between 11.1 and 13.9 mmol/L (200 and 250 mg/dL), give 4 units if the level is between 13.9 and 16.7 mmol/L (250 and 300 mg/dL), and so forth.

Computerized medical information systems can improve feedback control at many levels of the health care process. They can help to gather the state variables needed on the "sensory" side of the control loop. In intensive care, computer systems monitor blood pressure, heart rate, and ventricular rhythm. In primary care, computers remind physicians when it is time for a woman's mammogram or a diabetic patient's fundoscopic examination [2]. Computers can also suggest the specific adjustments to the control variables needed to correct an out-of-control state. For example, computers can suggest specific adjustments to the dose of heparin to reach a stated target goal (for example, an APTT between 2 and 2.5 times control). In medicine, computer-based feedback systems more often include a human (physician or nurse) in the feedback loop, but the principle is the same.

Much of diabetic care depends on relatively few laboratory variables (for example, serum glucose and glycosylated hemoglobin levels) combined with patient responses to a few questions (for example, their level of exercise and the time and amount of meals). Much of this information is already available to computers from laboratory systems and home glucometers. For these reasons, diabetes is especially well suited to computer-assisted feedback control.


Closed-Loop Systems (Where the Computer Does It All)
space

Closed-loop control systems have great potential for improving health outcomes and reducing costs. Such systems measure the state variables directly with sensors, "decide" what dose of the control variable to "prescribe," and deliver it automatically. The typical closed-loop control system measures and adjusts the control variables continuously—like the computerized fuel injectors in a modern automobile. The protocols in closed-loop medical systems typically consist of specific equations that relate state variables to the needed changes in control variables.

Closed-loop control systems are not new to medicine. Sheppard and Kouchoukos [3] pioneered their use in the 1970s. Their system automatically infused fluids postoperatively according to the patient's pulse, hemoglobin, and blood pressure levels, and it shortened postoperative intensive care time. Other closed-loop control systems infuse nitroprusside [4, 5] and oxytocin [6] to provide faster results, with less medicine and fewer overshoots than manually controlled infusion of the same medication.

Implantable defibrillators are a successful example of closed-loop control. Like cardiac pacemakers, they are implanted in the chest, monitor the patient's cardiac rhythm, and can provide electrical shocks to control specific aberrant rhythms. However, they can deliver much more electrical voltage than a pacemaker, with the capability of converting even a ventricular fibrillation to a normal rhythm. Studies show that implantable defibrillators do successfully convert ventricular fibrillation to correct arrhythmias [7].

In laboratory settings, insulin infusion pumps and glucose sensors under computer control can provide glucose control analogous to the human pancreas. Indeed, they are the components of a hoped-for artificial pancreas [8]. However, the development of automated systems for longterm, computer-controlled drug delivery has been stymied by the irascible behavior of biologic fluids. Clots and fibrosis confuse intravascular sensors and clog infusion pumps [9]. For now, the computer-controlled mechanical pancreas eludes us.


Open-Loop Control Systems
space

Unlike closed-loop systems, most medical computer feedback control systems have a human in the loop, who either gathers or sends the state variables, reviews or revises the computer's advice, or dispenses the medication.

Some of the oldest open-loop control systems are standalone computers that recommend dosages of digoxin, aminoglycosides, and theophylline. Typically, these programs estimate kinetic constants from the serum levels obtained after the first dose of the medication. These programs provide better drug levels than do unassisted physicians [10].

The computation of an optimal insulin dose is more difficult because insulin requirements depend on the patient's compliance with both dietary and exercise prescriptions and the timing of meals and exercise as well as the insulin dose and its excretion kinetics. Simple kinetic models do not provide perfect dose predictions. Furthermore, determining the "dose-response" of glucose control to exercise is expensive in both money and time, which is not practical in most settings [11]. Therefore, researchers have developed and tested more pragmatic models for both training and practice [12-16].

Home glucose monitoring systems can now retain the values of the glucose results and other variables for weeks to months, providing a convenient source of data for feedback control. Many vendors have tested products that collect patient data and transmit it to physicians by telephone for review. Some of these systems also provide advice about dosing. By alerting physicians early to trends, such systems offer the promise of improved glycemic control and better patient outcomes. In the largest and best randomized clinical trial of transmission of home glucose results to providers for review, Marrero and colleagues [17] found no difference in patient outcomes or levels of glucose control among intervention patients compared with control patients. However, the patients in the study already had good glucose level control at the outset, making it more difficult to show an effect. Smaller studies have shown some advantages to computer feedback [16], and noncomputerized suggestions to providers about heparin dosing did improve outcomes. Therefore, we are positive about the potential of computer-based insulin dose adjustment [18, 19].

How and when the feedback from computer protocols is delivered greatly influences the adoption of computer-based feedback systems. Stand-alone consulting systems that require the physician to go to a special device, initiate a dialogue, and describe the patient to the computer (for example, give the last blood urea nitrogen level, weight, insulin doses, and so forth) are not likely to be successful in a clinical setting, although they may be useful educational tools. Physicians will resist such systems because the benefits only rarely outweigh the time cost of using the system. Moreover, such systems cannot provide assistance unless the physician recognizes when he or she needs help and makes the effort to use the computer.

When the computer carries the relevant patient information in an electronic medical record system that the physician routinely accesses, it can offer reminders ("advice") without requiring extra physician effort or time, and physician acceptance comes more easily [20]. Almost all successful trials of open-loop feedback to physicians come from electronic medical record systems with automatic reminder capability [21-28], and such systems can have a large effect on the care process. Computer reminders produced increases up to fourfold in the use of preventive care among eligible patients in a long-term trial at our institution [2].

Open-loop rules can be quite complex. Figure 1 shows the rules that the HELP system at LDS Hospital in Salt Lake City, Utah, uses to govern the ventilator settings of patients with acute respiratory distress syndrome [22]. The computer generates reminders to physicians when the rules call for ventilator adjustments. Physicians, not the computer, then make the final decision about the ventilator settings.



View larger version (47K):
[in this window]
[in a new window]
 
Figure 1. Rules for acute respiratory distress syndrome. (Reprinted with permission from LDS Hospital.).

 

The protocols in open-loop systems can, on the other hand, be quite simple. Table 1 shows part of the rules that guide the use of influenza vaccine in the Regenstrief Medical Record System. The first rule in the Table definesexclusion criteria, for example, patients who have already either received or refused the vaccine during the past year. Succeeding rules suggest influenza vaccine for patients with chronic obstructive lung disease, or diabetes. Other rules (not shown) remind about using a flu shot in patients with congestive heart failure, renal failure, and advanced age (> 65 years old). The braces identify variables that will be replaced with patient-specific data when the reminders are displayed to the physician.


View this table:
[in this window]
[in a new window]
 
Table 1. Reminder Rules from the Regenstrief Medical Record System

 

The second part of Table 1 shows one of many rules related to diabetes in pregnancy. The first block defines patients at high risk during pregnancy, and the second generates a message to the physician (or obstetrical nurse) about the needed test. The last example Table 2 shows yet another Regenstrief Medical Record System rule (in a somewhat different syntax) that reminds physicians to treat diabetic patients who have proteinuria with angiotensin-converting enzyme (ACE) inhibitors. Exclusion criteria are not shown in Table 2. The computer processes these rules and presents precomposed orders to a physician as she or he begins a computer order-writing session. The physician can accept or reject any suggested orders.


View this table:
[in this window]
[in a new window]
 
Table 2. Rule from the Regenstrief Medical Record System Reminding Physicians To Use Initial Angiotensin-Converting Enzyme (ACE) Inhibitor Therapy in Diabetic Patients with Proteinuria

 

We have implemented many open-loop rules to guide the management of diabetic patients, including those to remind physicians to do the following:

- test glycosylated hemoglobin

- screen for cholesterol abnormalities

- avoid oral hypoglycemic agents in high-risk patients (for example, alcoholic persons)

- prescribe aspirin for diabetic patients who have at least one other cardiovascular risk factor

- treat hypertensive diabetic patients with ACE inhibitors to protect their kidneys

- refer patients for a fundoscopic examination at intervals, depending on the type and duration of diabetes.

Physicians wrote the rules shown in Tables 1 and 2 using a formal syntax that the computer can "understand" directly. Our institution does 70 000 medicine or medicine subspecialty visits, 30 000 obstetrical visits, and 30 000 pediatric visits each year, and before all of them, the computer reviews the patient's computer-stored record according to these rules and reminds the physician when it finds conditions needing attention.

The American Diabetes Association (ADA) regularly publishes several clinical practice recommendations for management issues [29]. Many of these could, in theory, also be implemented as open-loop computer reminders. However, some of these recommendations are difficult to transform into operational computer rules because they lack the precise criteria for specifying what action should be taken and when. In a patient with a foot ulcer, for example, the guidelines suggest that radiologic examination may be required to exclude subcutaneous gas, presence of a foreign body, osteomyelitis, and Charcot foot. This does not provide much direction. Is it really saying that one should obtain a radiologic examination at least once in most diabetic patients with foot ulcers? Or is it saying that one should obtain a radiologic study if one suspects a foreign body, osteomyelitis, or Charcot foot? The guideline goes on to say that a triple-phase bone scan, indium-tagged leukocyte study, magnetic resonance imaging scan, or bone biopsy might be required but gives no criteria for choosing among the four. The computer requires precise instructions for when to deliver a reminder.

On the other hand, the ADA guidelines provide some precise rules that would be easy to implement through a computer. For example, they suggest ordering tests for glycosylated hemoglobin, thyroid-stimulating hormone, thyroxine, high-density lipoprotein and low-density lipoprotein cholesterol, and triglyceride levels, urinalysis, and electrocardiography at the first visit of a diabetic patient more than 40 years old. Here, however, the scientific support for doing these studies is not included in the guideline report. Some authors suggest not routinely obtaining chest radiographs even for hospitalized patients in the absence of symptoms or special risks [30], and some would argue against routine electrocardiograms in the absence of cardiac symptoms or findings [31]. Most ADA guidelines about testing can be justified, but we wish that the scientific rationales were included in the report to save readers the requisite literature searches needed to support the guidelines locally. Such justification will be necessary if the ADA recommendations are to become accepted routine care; at our institution, these recommended first-visit tests cost $293.


Conclusions
space

In the United States, most diabetic care (85%) is provided by generalists rather than diabetologists [32, 33]. That ratio cannot change much, given the relatively small number of diabetologists. By producing and validating diabetes guidelines that could be implemented as open loops in electronic medical record systems, diabetologists could reach many more diabetic patients. First, however, more detailed justifications and more precise specifications are required. The need for precision in the guidelines is all the more important as we strive for tighter control of diabetic patients and skim closer to the hypoglycemic side of the treatment window. Eddy [34] and Tierney and colleagues [35] provide good advice about building guidelines, and Gunnar and colleagues [36] provide a great example of the value of tying guidelines to the supporting medical literature. However, information for deciding many of the details of diabetic care is likely not available in the current medical literature, and more primary studies are needed to define the precise relation between patient state variables and some of the actions needed. The Ottawa ankle guidelines provide a good example of how to do this [37].


Author and Article Information
space
up arrowTop
dotAuthor & Article Info
down arrowReferences

From the Regenstrief Institute for Health Care and the Indiana University School of Medicine, Indianapolis, Indiana.
Note: This article is one of a series of articles comprising an Annals of Internal Medicine supplement entitled "Risks and Benefits of Intensive Management in Non-Insulin-dependent Diabetes Mellitus: The Fifth Regenstrief Conference." To view a complete list of the articles included in this supplement, please view its Table of Contents.
Acknowledgments: The work was done at the Regenstrief Institute for Health Care.
Grant Support: In part, by contract N01-LM-4-3510 from the National Library of Medicine and grant R01 HS07719-01 from the Agency for Health Care Policy and Research.
Requests for Reprints: Clement J. McDonald, MD, Regenstrief Institute for Health Care, 1001 West 10th Street, Indianapolis, IN 46202.
Current Author Addresses: Drs. McDonald, Overhage, Tierney, Abernathy, and Dexter: Regenstrief Institute for Health Care, 1001 West 10th Street, Indianapolis, IN 46202.


References
space
up arrowTop
up arrowAuthor & Article Info
dotReferences

1. Westenskow DR. Automating patient care with closed-loop control MD Comput. 1986;3:14-20.

2. McDonald CJ, Hui SL, Smith DM, Tierney WM, Cohen SJ, Weinberger M, et al. Reminders to physicians from an introspective computer medical record. A two-year randomized trial Ann Intern Med. 1984;100:130-8.

3. Sheppard LC, Kouchoukos NT. Automation of measurements and interventions in the systematic care of postoperative cardiac surgical patients Med Instrum. 1977;11:296-301.

4. Ying H, Sheppard LC. Real-time expert-system-based fuzzy control of mean arterial pressure in pigs with sodium nitroprusside infusion Med Prog Technol. 1990;16:69-76.

5. Meline LI, Westenskow DR, Pace NL, Bodily MN. Computer-controlled regulation of sodium nitroprusside infusion Anesth Analg. 1985;64:38-42.

6. "Modular labour-management system. J Med Eng Technol. 1982; 6:89-92.".

7. Zipes DP. The Implantable cardioverter defibrillator revolution continues [Editorial] Mayo Clin Proc. 1994;69:395-6.

8. Buchwald H, Rohde TD. Implantable pumps. Recent progress and anticipated future advances ASAIO J. 1992;38:772-8.

9. Saudek CD. Future developments in insulin delivery systems Diabetes Care. 1993;16(Suppl 3):122-32.

10. Jelliffe RW, Maire P, Sattler F, Gomis P, Tahani B. Adaptive control of drug dosage regimens: basic foundations, relevant issues, and clinical examples Int J Biomed Comput. 1994;36:1-23.

11. Marrero DG. Computers and the assessment of diabetes control. In: Mogensen CE, Standl E; eds. Concepts for the Ideal Diabetes Clinic. New York: Walter de Gruyter; 1993:375-88.

12. Chiarelli F, Tumini S, Morgese G, Albisser AM. Controlled study in diabetic children comparing insulin-dosage adjustment by manual and computer algorithms Diabetes Care. 1990;13:1080-4.

13. Deutsch T, Boroujerdi MA, Carson ER, Harvey FE, Sonksen PH, Tamas G, et al. The principles and prototyping of a knowledge-based diabetes management system Comput Methods Programs Biomed. 1989;29:75-88.

14. Marrero DG, Kronz KK, Golden MP, Wright JC, Orr DP, Fineberg NS. Clinical evaluation of computer-assisted self-monitoring of blood glucose system Diabetes Care. 1989;12:345-50.

15. Berger MP, Gelfand RA, Miller PL. Combining statistical, rule-based, and physiologic model-based methods to assist in the management of diabetes mellitus Comput Biomed Res. 1990;23:346-57.

16. Peterson CM, Jovanovic L, Chanoch LH. Randomized trial of computerassisted insulin delivery in patients with type I diabetes beginning pump therapy Am J Med. 1986;81:69-72.

17. Marrero D, Vandagriff JL, Kronz K, Fineberg NS, Golden MP, Gray D, et al. Using telecommunication technology to manage children with diabetes: the computer-linked outpatient clinic (CLOC) study Diabetes Educ. 1995;21:313-9.

18. Raschke RA, Reilly BM, Guidry JR, Fontana JR, Srinivas S. The weightbased heparin dosing nomogram compared with a standard care nomogram. A randomized controlled trial Ann Intern Med. 1993;119:874-81.

19. Landefeld CS, Anderson PA. Guideline-based consultation to prevent anticoagulant-related bleeding. A randomized, controlled trial in a teaching hospital Ann Intern Med. 1992;116:829-37.

20. McDonald CJ, Tierney WM, Overhage JM, Martin DK, Wilson GA. The Regenstrief Medical Record System: 20 years of experience in hospitals, clinics, and neighborhood health centers MD Comput. 1992;9:206-17.

21. Rind DM, Safran C, Phillips RS, Wang Q, Calkins DR, Delbanco TL, et al. Effect of computer-based alerts on the treatment and outcomes of hospitalized patients Arch Intern Med. 1994;154:1511-7.

22. East TD, Bohm SH, Wallace CJ, Clemmer TP, Weaver LK, Orme JF, et al. A successful computerized protocol for clinical management of pressure control inverse ratio ventilation in ARDS patients Chest. 1992;101:697-710.

23. Litzelman DK, Dittus RS, Miller ME, Tierney WM. Requiring physicians to respond to computerized reminders improves their compliance with preventive care protocols J Gen Intern Med. 1993;8:311-7.

24. McPhee SJ, Bird JA, Fordham D, Rodnick JE, Osborn EH. Promoting cancer prevention activities by primary care physicians. Results of a randomized, controlled trial JAMA. 1991;266:538-44.

25. McDonald CJ. Protocol-based computer reminders, the quality of care and the non-perfectability of man N Engl J Med. 1976;295:1351-5.

26. Barnett GO. The application of computer-based medical-record systems in ambulatory practice N Engl J Med. 1984;310:1643-50.

27. McPhee SJ, Bird JA, Fordham D, Rodnick JE, Osborn EH. Promoting cancer prevention activities by primary care physicians. Results of a randomized, controlled trial JAMA. 1991;266:538-44.

28. Haug PJ, Gardner RM, Tate KE, Evans RS, East TD, Kuperman G, et al. Decision support in medicine: examples from the HELP system Comput Biomed Res. 1994;27:396-418.

29. "American Diabetes Association position statement. Standards of medical care for patients with diabetes mellitus. Diabetes Care. 1993; 16(Suppl 2):10-3.".

30. Hubbell FA, Greenfield S, Tyler JL, Chetty K, Wyle FA. The impact of routine admission chest x-ray films on patient care N Engl J Med. 1985;312:209-13.

31. Rubenstein LZ, Greenfield S. The baseline ECG in the evaluation of acute cardiac complaints JAMA. 1980;244:2536-9.

32. Marrero DG, Moore PS, Fineberg NS, Langefeld CD, Clark CM. The treatment of patients with insulin-requiring diabetes mellitus by primary care physicians J Community Health. 1991;16:259-67.

33. Levy P. Implications of the DCCT for national health care reform Diabetes Reviews. 1994;2:368-70.

34. Eddy D. A Manual for Assessing Health Practices and Designing Practice Policies: The Explicit Approach. Philadelphia: American College of Physicians; 1992.

35. Tierney WM, Overhage JM, McDonald CJ. A plea for controlled trials in medical informatics [Editorial] J Am Med Inform Assoc. 1994;1:353-5.

36. Gunnar RM, Passamani ER, Bourdillon PD, Pitt B, Dixon DW, Rapaport E, et al. Guidelines for the early management of patients with acute myocardial infarction. A report of the American College of Cardiology/American Heart Association Task Force on Assessment of Diagnostic and Therapeutic Cardiovascular Procedures J Am Coll Cardiol. 1990;16:249-92.

37. Stiell IG, McKnight RD, Greenberg GH, McDowell I, Nair RC, Wells GA, et al. Implementation of the Ottawa ankle rules JAMA. 1994;271:827-32.


This article has been cited by other articles:


Home page
J. Am. Med. Inform. Assoc.Home page
S. T. Rosenbloom, K.-W. Chiu, D. W. Byrne, D. A. Talbert, E. G. Neilson, and R. A. Miller
Interventions to Regulate Ordering of Serum Magnesium Levels: Report of an Unintended Consequence of Decision Support
J. Am. Med. Inform. Assoc., September 1, 2005; 12(5): 546 - 553.
[Abstract] [Full Text] [PDF]


Home page
J. Am. Med. Inform. Assoc.Home page
S. T. Rosenbloom, A. J. Geissbuhler, W. D. Dupont, D. A. Giuse, D. A. Talbert, W. M. Tierney, W. D. Plummer, W. W. Stead, and R. A. Miller
Effect of CPOE User Interface Design on User-Initiated Access to Educational and Patient Information during Clinical Care
J. Am. Med. Inform. Assoc., July 1, 2005; 12(4): 458 - 473.
[Abstract] [Full Text] [PDF]


Home page
American Journal of Medical QualityHome page
E. F. Ellerbeck, K. K. Engelman, N. J. Williams, N. Nazir, and S. J. Markello
Variations in Diabetes Care and the Influence of Office Systems
American Journal of Medical Quality, January 1, 2004; 19(1): 12 - 18.
[Abstract] [PDF]


Home page
J. Am. Med. Inform. Assoc.Home page
J. Michael Fitzmaurice, K. Adams, and J. M. Eisenberg
Three Decades of Research on Computer Applications in Health Care: Medical Informatics Support at the Agency for Healthcare Research and Quality
J. Am. Med. Inform. Assoc., March 1, 2002; 9(2): 144 - 160.
[Abstract] [Full Text] [PDF]


Home page
J. Am. Med. Inform. Assoc.Home page
P. C. Tang, M. P. LaRosa, C. Newcomb, and S. M. Gorden
Measuring the Effects of Reminders for Outpatient Influenza Immunizations at the Point of Clinical Opportunity
J. Am. Med. Inform. Assoc., March 1, 1999; 6(2): 115 - 121.
[Abstract] [Full Text] [PDF]


Home page
J. Am. Med. Inform. Assoc.Home page
R. D. Zielstorff
Online Practice Guidelines: Issues, Obstacles, and Future Prospects
J. Am. Med. Inform. Assoc., May 1, 1998; 5(3): 227 - 236.
[Abstract] [Full Text]


Home page
J. Am. Med. Inform. Assoc.Home page
S. B. Henry, K. Douglas, G. Galzagorry, A. Lahey, and W. L. Holzemer
A Template-based Approach to Support Utilization of Clinical Practice Guidelines Within an Electronic Health Record
J. Am. Med. Inform. Assoc., May 1, 1998; 5(3): 237 - 244.
[Abstract] [Full Text]


box Article
 arrow  Table of Contents                
space
 arrow  Abstract of this article Free
space
 arrow  Figures/Tables List
space
 arrow  Articles citing this article
space
box Services
 arrow  Send comment/rapid response letter
space
 arrow  Notify a friend about this article
space
 arrow  Alert me when this article is cited
space
 arrow  Add to Personal Archive
space
 arrow  Download to Citation Manager
space
 arrow  ACP Search                        
space
 arrow  Get Permissions
space
box Google Scholar
 arrow  Search for Related Content
space
box PubMed
Articles in PubMed by Author:
  arrow  McDonald, C. J.
space
  arrow  Dexter, P. R.
space
 arrow  Related Articles in PubMed
space
 arrow  PubMed Citation
space
 arrow  PubMed
space


 Home | Current Issue | Past Issues | In the Clinic | ACP Journal Club | CME | Collections | Audio/Video | Mobile | Subscribe | Tools | Help | ACP Online