Home |
Current Issue |
Past Issues |
In the Clinic |
ACP Journal Club |
CME |
Collections |
Audio/Video |
Mobile |
Subscribe |
Tools |
Help |
ACP Online
|
| |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
15 October 1997 | Volume 127 Issue 8 Part 1 | Pages 588-595
Background: Continuous positive airway pressure (CPAP) is effective therapy for the obstructive sleep apnea syndrome (OSAS). Automatic CPAP devices continuously adjust the positive pressure to the required levels.
Objective: To determine the efficacy of an automatic CPAP machine used with an estimated reference pressure value.
Design: A before-and-after, single-blind trial in which patients were randomly allocated to one of three modes of CPAP administration.
Setting: Referral-based sleep center in a public health care institution.
Patients: 36 outpatients with OSAS.
Intervention: Continuous positive airway pressure was given at a conventional fixed pressure (group 1), automatic CPAP was given at a measured reference pressure (group 2), and automatic CPAP was given at an estimated reference pressure (group 3). In group 1, the effective pressure was determined during a titration sleep study. In groups 2 and 3, the pressure interval was allowed to vary from 4 cm H2O below reference pressure to 3 cm H2O above reference pressure. In group 3, the estimated value of the reference pressure was determined according to individual anthropometric characteristics.
Measurements: Sleep studies were performed and measurements of diurnal sleepiness were obtained at each visit.
Results: Sleep and breathing disorders and hypersomnolence were alleviated similarly in the three groups. The apnea + hypopnea index remained abnormal in one patient in group 3 for whom the reference pressure had been underestimated. A strong negative correlation was found between the percentage of time spent below reference pressure during CPAP and the difference between the effective and estimated pressures.
Conclusion: Automatic CPAP can be used with an estimated reference pressure without doing a titration sleep study. The positive pressure trend can be used to determine whether treatment failure is caused by an inadequate pressure setting and to determine the amount of pressure to apply.
Author and Article Information
From Hopital Laval, Sainte-Foy, Quebec, Canada
ARTICLE
Efficacy of Automatic Continuous Positive Airway Pressure Therapy That Uses an Estimated Required Pressure in the Treatment of the Obstructive Sleep Apnea Syndrome
![]()
Acknowledgment: The authors thank Nathalie Dupuis, Andree Veilleux, Sandra Jolin, Michel Leblond, Isabelle Boucher, and Germain Ethier for technical assistance and Serge Simard for statistical analysis.
Grant Support: In part by Pierre Medical France.
Requests for Reprints: Frederic Series, MD, Centre de pneumologie, Hopital Laval, 2725 chemin Sainte-Foy, Sainte-Foy, Quebec G1V 4G5, Canada.
Current Author Addresses: Drs. Series and Marc: Centre de pneumologie, Hopital Laval, 2725 chemin Sainte-Foy, Sainte-Foy, Quebec G1V 4G5, Canada.
Related articles in Annals:
This article has been cited by other articles:
![]() |
J. F. Masa, A. Jimenez, J. Duran, F. Capote, C. Monasterio, M. Mayos, J. Teran, L. Hernandez, F. Barbe, A. Maimo, et al. Alternative Methods of Titrating Continuous Positive Airway Pressure: A Large Multicenter Study Am. J. Respir. Crit. Care Med., December 1, 2004; 170(11): 1218 - 1224. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Abdenbi, B. Chambille, and P. Escourrou Bench testing of auto-adjusting positive airway pressure devices Eur. Respir. J., October 1, 2004; 24(4): 649 - 658. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. Senn, T. Brack, F. Matthews, E. W. Russi, and K. E. Bloch Randomized Short-term Trial of Two AutoCPAP Devices versus Fixed Continuous Positive Airway Pressure for the Treatment of Sleep Apnea Am. J. Respir. Crit. Care Med., December 15, 2003; 168(12): 1506 - 1511. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.C. Rudkowski, P. Verschelden, and R.J. Kimoff Efficacy of daytime continuous positive airway pressure titration in severe obstructive sleep apnoea Eur. Respir. J., September 1, 2001; 18(3): 535 - 541. [Abstract] [Full Text] [PDF] |
||||