Annals
Established in 1927 by the American College of Physicians
:
Advanced search
 
box Article
 arrow  Table of Contents                
space
 arrow  Full Text of this article Free
space
 arrow  Figures/Tables List
space
box Services
 arrow  Send comment/rapid response letter
space
 arrow  Notify a friend about this article
space
 arrow  Alert me when this article is cited
space
 arrow  Add to Personal Archive
space
 arrow  Download to Citation Manager
space
 arrow  ACP Search                        
space
 arrow  Get Permissions
space
box Google Scholar
 arrow  Search for Related Content
space
box PubMed
Articles in PubMed by Author:
  arrow  Flaherty, J. P.
space
  arrow  Arnow, P. M.
space
 arrow  Related Articles in PubMed
space
 arrow  PubMed Citation
space
 arrow  PubMed
space

ARTICLE

An Outbreak of Gram-negative Bacteremia Traced to Contaminated O-Rings in Reprocessed Dialyzers

right arrow John P. Flaherty; Sylvia Garcia-Houchins; Robert Chudy; and Paul M. Arnow

1 December 1993 | Volume 119 Issue 11 | Pages 1072-1078

Objective: To investigate an outbreak of gram-negative bacteremia in an outpatient hemodialysis unit and to identify the source of contaminating bacteria and the route by which bacteria gained access to the bloodstream.

Design: A matched-pair, case–control study and a bacteriologic investigation of the hemodialysis unit and the implicated dialyzers.

Setting: A university outpatient hemodialysis unit.

Patients: Eleven patients receiving long-term hemodialysis who had a total of 12 episodes of primary gram-negative bacteremia and 12 matched controls.

Measurements: Clinical and demographic data were obtained for patients and controls. Dialysis unit procedures were observed for compliance with aseptic technique. Cultures of potential environmental sources of bacteria were obtained. Hemodialyzers from bacteremic and nonbacteremic patients were dismantled, and the component parts were cultured. Inoculation of O-rings (from Hemoflow F-80 dialyzer) with bacteria and simulated dialysis were done.

Results: During January to October 1988, 12 episodes of primary gram-negative bacteremia caused by Pseudomonas cepacia, Xanthomonas maltophilia, Citrobacter freundii, Acinetobacter calcoaceticus var. anitratus, or Enterobacter cloacae occurred in 11 patients. In 11 episodes, symptoms developed within 3 hours of starting hemodialysis. Intravenous antibiotics were administered for 11 episodes, 3 episodes resulted in hospitalization, and all patients recovered. Case patients were more likely to have received high-flux dialysis with Hemoflow F-80 dialyzers (odds ratio 11) than were controls. O-rings from dialyzers used by bacteremic patients were culture positive for the organism responsible for bacteremia. Three of the four dialyzers were disinfected using the standard automated method and were recultured 72 hours later; the O-rings of all three dialyzers remained culture positive. Simulated dialysis using dialyzers with contaminated O-rings caused blood pathway contamination despite intervening reprocessing. When the disinfection method for F-80 dialyzers included removal and complete disinfection of the O-rings, O-ring and blood pathway cultures were consistently negative. After this procedure was made routine, no episodes of primary gram-negative bacteremia occurred during the next 6 months.

Conclusions: Because dialyzers with removable headers and O-rings are widely used in patients receiving long-term hemodialysis, disinfection procedures should include measures to ensure adequate disinfection of O-rings.

Author and Article Information
space

From the University of Chicago, Chicago, Illinois.
Requests for Reprints: John P. Flaherty, MD, University of Chicago Hospital, MC 5065, 5841 South Maryland Avenue, Chicago, IL 60637.
Acknowledgments: The authors thank Dr. Susan Fellner and Michael Carey for technical assistance.




This article has been cited by other articles:


Home page
Arch Intern MedHome page
J. T. Watson, R. C. Jones, A. M. Siston, J. R. Fernandez, K. Martin, E. Beck, S. Sokalski, B. J. Jensen, M. J. Arduino, A. Srinivasan, et al.
Outbreak of Catheter-Associated Klebsiella oxytoca and Enterobacter cloacae Bloodstream Infections in an Oncology Chemotherapy Center
Arch Intern Med, December 12, 2005; 165(22): 2639 - 2643.
[Abstract] [Full Text] [PDF]


Home page
J Med MicrobiolHome page
A. V. Souza, C. R. Moreira, J. Pasternak, M. d. L. Hirata, D. A. Saltini, V. C. Caetano, S. Ciosak, F. M. Azevedo, P. Severino, P. Vandamme, et al.
Characterizing uncommon Burkholderia cepacia complex isolates from an outbreak in a haemodialysis unit
J. Med. Microbiol., October 1, 2004; 53(10): 999 - 1005.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Microbiol.Home page
J. W. Krzewinski, C. D. Nguyen, J. M. Foster, and J. L. Burns
Use of Random Amplified Polymorphic DNA PCR To Examine Epidemiology of Stenotrophomonas maltophilia and Achromobacter (Alcaligenes) xylosoxidans from Patients with Cystic Fibrosis
J. Clin. Microbiol., October 1, 2001; 39(10): 3597 - 3602.
[Abstract] [Full Text] [PDF]


Home page
J. Clin. Microbiol.Home page
M. Denton, N. J. Todd, K. G. Kerr, P. M. Hawkey, and J. M. Littlewood
Molecular Epidemiology of Stenotrophomonas maltophilia Isolated from Clinical Specimens from Patients with Cystic Fibrosis and Associated Environmental Samples
J. Clin. Microbiol., July 1, 1998; 36(7): 1953 - 1958.
[Abstract] [Full Text]


Home page
Clin. Microbiol. Rev.Home page
M. Denton and K. G. Kerr
Microbiological and Clinical Aspects of Infection Associated with Stenotrophomonas maltophilia
Clin. Microbiol. Rev., January 1, 1998; 11(1): 57 - 80.
[Abstract] [Full Text] [PDF]




 Home | Current Issue | Past Issues | In the Clinic | ACP Journal Club | CME | Collections | Audio/Video | Mobile | Subscribe | Tools | Help | ACP Online 

Copyright © 1993 by the American College of Physicians.